<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-24 03-23-10
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 71 dBuV YLEX
Pilot RDS Phase Difference
7.4 kHz 2.3 kHz 56 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 63 kHz 19059 0,5247
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,6 dBr 3,39 dBr 4,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 3:23, 24.05.2025
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6207, 6205, 6201, 6203
FM Scope Max at: 63 kHz MIN: 9 kHz % above 76 kHz: 0,5247 Acquired: 2025/05/24 3.22.07 Total samples: 19059 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 4,8 dBr MIN: 1,6 dBr AVE: 3,39 dBr % above 12,2 dBr: 0,0 Last value: 1,8 dBr (2025/05/24 3.22.06) 03.08 03.10 03.12 03.14 03.16 03.18 03.20 03.22 0 2 4 Pm [dBr]